This paper describes the innovative use of a Buckling Restrained Brace Frame (BRBF) system in the seismic retrofit of an existing non-ductile concrete building in Southern California. The building, designed in the early 1960's and used as a medical office building, is approximately 148 feet by 158 feet in plan with seven stories above grade and three stories below grade. In addition there is a two-story penthouse above the main roof level. Typical floor and roof framing consists of a reinforced-concrete slab and beam system. The original lateral load resisting system of the building consisted of reinforced concrete floor and roof diaphragms that transfer seismic inertial loads to reinforced concrete shear walls. The existing concrete walls were poorly distributed making the building highly irregular in torsion. Although the building is located approximately 25 miles from the epicenter of the 1994 Northridge Earthquake, it suffered significant structural damage requiring extensive structural repair. A performance-based seismic evaluation was performed and from that a retrofit scheme was developed to achieve at a minimum the "Collapse Prevention" performance level of FEMA- 356. The design team was asked to develop a seismic retrofit scheme, which is cost effective, aesthetically acceptable, non-intrusive, and essentially allowed the building to remain open and operational throughout the construction. The retrofit solution developed using the BRBF system exceeded the expectations of the owner and received high praise from the city for improving the aesthetic appeal of the building and all at a cost significantly less than the owner's budget which was based on a conventional retrofit design developed by others. This paper will describe the analysis performed, the design of the BRBF retrofit scheme, and the logistics and challenges of the construction.
机译:本文介绍了屈曲约束支撑框架(BRBF)系统在南加州现有非延性混凝土建筑的抗震改造中的创新用法。该建筑于1960年代初设计,用作医疗办公大楼,平面图约为148英尺乘158英尺,其中地上七层,地下三层。此外,在主屋顶上方还有两层的顶层公寓。典型的地板和屋顶框架由钢筋混凝土板和梁系统组成。建筑物最初的抗侧向荷载系统由钢筋混凝土地板和屋顶隔板组成,将地震惯性荷载传递到钢筋混凝土剪力墙。现有的混凝土墙分布不均,使建筑物的扭转高度不规则。尽管该建筑距离1994年Northridge地震的震中约25英里,但它遭受了重大的结构破坏,需要进行大量的结构修复。进行了基于性能的地震评估,并从中开发了改造方案,以至少达到FEMA-356的“防塌”性能水平。要求设计团队开发一种成本效益高的地震改造方案,从美学上讲是可接受的,非侵入性的,并且实质上允许建筑物在整个建筑物中保持开放和可操作。使用BRBF系统开发的翻新解决方案超出了业主的期望,并因改善建筑物的美学吸引力而受到了城市的高度赞扬,并且所有成本都大大低于业主的预算,而该预算是基于由BF开发的传统翻新设计的其他。本文将介绍进行的分析,BRBF改造方案的设计以及建设的物流和挑战。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号