摘要

Partial discharge (PD) is the main cause of the failure of power apparatus insulation. The detection of PD in the early stage is useful to understand the condition of power apparatus, to design predictive maintenance program, and to prevent the breakdown of power apparatus. PD signal can be detected by the sensor. This paper deals with design of resistor capacitor (RC) circuit as PD detector. The PD detector was tested using a vector network analyzer. The bandwidth, the return loss, and the resonance frequency of the detection circuit were measured. The testing results show that the bandwidth of RC detector achieved 500 MHz. The PD detector was applied to measure PD occurring in the air insulation of needle-plane electrode. The measured PD parameters were PD inception voltage (PDIV), PD waveform PD, PD phase pattern, and PD pulse sequence. The testing results show that PD detector is able to measure PD.
机译:局部放电(PD)是导致电力设备绝缘失效的主要原因。 PD的早期检测有助于了解电力设备的状况,设计预测性维护程序并防止电力设备故障。 PD信号可以被传感器检测到。本文设计了电阻电容(RC)电路作为PD检测器的设计。使用矢量网络分析仪对PD检测器进行了测试。测量了检测电路的带宽,回波损耗和谐振频率。测试结果表明,RC检测器的带宽达到了500 MHz。 PD检测器用于测量在针平面电极的空气绝缘层中发生的PD。测得的PD参数为PD起始电压(PDIV),PD波形PD,PD相位图和PD脉冲序列。测试结果表明,PD探测器能够测量PD。