There were many harmonic and neutral current mitigation methods evolved earlier to address the power quality problem but each solution has its own limitation. A brief investigation is made into different neutral current compensation techniques available in literature and a detailed performance comparison of the techniques is made in this paper. The most common load in the distribution side of RL load is considered here. The different neutral current compensating techniques are compared through extensive simulations using MATLAB /SIMULINK power system block set with load as unbalanced RL controlled by an AC voltage regulator. An experimental verification for one of the technique under the mentioned load is taken and presented in this paper.
机译:为了解决电能质量问题,有许多谐波和中性线电流缓解方法较早发展,但是每种解决方案都有其自身的局限性。对文献中可用的不同中性点电流补偿技术进行了简要调查,并对该技术进行了详细的性能比较。此处考虑了RL负载在配电侧最常见的负载。通过使用MATLAB / SIMULINK电力系统模块进行广泛的仿真,比较了不同的中性点电流补偿技术,该模块的负载为交流稳压器控制的不平衡RL。本文对其中一种技术进行了实验验证,并在本文中进行了介绍。