The frequency depenence of the complex permeability fo iron powder dust cores was calculated for two cases, asuming either intra-particle or inter-particle eddy currents. Measured values in the frequency rnage of 10-Khz-2 MHz coincided well with the calculation which, between the two cases, gave larger core losses. Accordingly the complex permeability could be precisely predicted.