Comparative analyses of standards temperature rise test methods for induction machines

机译:感应电机标准温升测试方法的比较分析

获取原文

摘要

Induction machines temperature rise measurement is certainly a common demand of customers and manufacturers. The manufacturers have to optimize the product to be competitive, while the user wants to be sure that the motor is in accordance with the insulation temperature class limit. The most accepted condition to measure temperature rise in induction motors is under full load since it simulates the real operating conditions. However, it requires the use of dynamometers and sources of same or sometimes greater power than the rated power of machine under test. Additionally the coupling of high power, high speed or vertical machines can consume considerable time and investment. For these cases it is necessary to consider the use of alternative methods to measure the electrical machine temperature. In these alternative methods the load torque applied by the dynamometer is smaller than the motor nominal torque or even no load torque applied. This paper will present a comparison between the most common induction machines temperature rise methods.
机译:感应电机温升测量无疑是客户和制造商的共同需求。制造商必须优化产品以使其具有竞争力,而用户则要确保电动机符合绝缘温度等级限制。测量感应电动机温升的最公认条件是满载,因为它可以模拟实际运行条件。但是,它要求使用测功机,其功率应等于或有时大于被测机器的额定功率。另外,大功率,高速或垂直机器的耦合会消耗大量时间和投资。对于这些情况,有必要考虑使用替代方法来测量电机温度。在这些替代方法中,测功机施加的负载转矩小于电机额定转矩,甚至没有施加负载转矩。本文将对最常见的感应电机温升方法进行比较。