Advanced double-pulse UV source for laser-induced fluorescence of bio-aerosols

机译:先进的双脉冲紫外线源,用于激光诱导生物气溶胶的荧光

获取原文
获取原文并翻译 | 示例

摘要

To enhance discrimination of UV-laser-induced-fluorescence based bio-aerosol-detection-system, a UV-laser is described that allows multiple wavelength excitation of bio-aerosols and both fluorescence spectral and time-decay analysis. The latter requiring sub-ns pulse duration, a two-stage-amplifier boosts a 20-μJ-1064-nm-500-ps-actively-Q-Switch microchip-oscillator output energy up to 2.5 mJ. After frequency doubling and beam splitting, 20-μJ-293-and-337-nm pulses are generated by two different periodically-poled-KTP (parametric generation) and BBO (frequency doubling) crystal arrangements. In order to get distinct fluorescence signals for each wavelength, the beams are then time-delayed with two optical fibers of different lengths and launched into a chamber for bio-aerosol excitation connected to a fast detection system.
机译:为了增强对基于紫外激光诱导的荧光的生物气溶胶检测系统的辨别能力,描述了一种紫外激光,它允许生物气溶胶的多波长激发以及荧光光谱和时间衰减分析。后者需要亚纳秒的脉冲持续时间,两级放大器将20μJ-1064nm-500ps有源Q开关微芯片振荡器的输出能量提升至2.5mJ。在倍频和分束之后,通过两种不同的周期性极化KTP(参数生成)和BBO(倍频)晶体排列生成20μJ-293和337nm脉冲。为了获得每种波长的不同荧光信号,然后用两条不同长度的光纤对光束进行延时,然后将其发射到与快速检测系统相连的用于生物气溶胶激发的腔室中。