首页> 外文会议>Optical Tomography and Spectroscopy of Tissue VII; Progress in Biomedical Optics and Imaging; vol.8 no.11; Proceedings of SPIE-The International Society for Optical Engineering; vol.6434 >Two-dimensional/three dimensional Hybrid Interstitial Diffuse Optical Tomography of Human Prostate during Photodynamic Therapy: Phantom and Clinical Results
【24h】

Two-dimensional/three dimensional Hybrid Interstitial Diffuse Optical Tomography of Human Prostate during Photodynamic Therapy: Phantom and Clinical Results

机译:人前列腺摄动期间的二维/三维混合间质扩散光学层析成像:幻影和临床结果

获取原文
获取原文并翻译 | 示例

摘要

We have developed an efficient Levenberg-Marquardt iterative algorithm utilizing a three-dimensional field measurements coupled to a two-dimensional optical property reconstruction scheme. This technique takes advantage of accurate estimation of light distribution in 3D forward calculation and reduced problem size and less computation time in 2D inversion. Important advances in terms of improving algorithm efficiency and accuracy include use of an iterative general minimum residual method (GMRES) for computing the field solutions, application of the dual mesh scheme and adjoint method for Jacobian construction, and implementation of normalization scheme to reduce the absorption-scattering cross talk. The synthetic measurement data were calculated for a cubic phantom containing a single absorption anomaly and a single scattering anomaly. The model had a background of μ_a=0.03mm~(-1) and μ_s'=1.4mm~(-1). The absorption and scattering anomalies have the μ_a = 0.06 mm~(-1) and μ_s' = 2.0 mm~(-1). Five sources and 72 detectors are used per slice. A typical human prostate is composed of 6 slices. The reconstruction images successfully recover the both anomalies with good localization. Experiment data from tissue simulated phantom are also presented. The clinical DOT imaging was performed before photodynamic therapy based on the protocol. The preliminary results showed the reconstructed prostate μa varied between 0.025 and 0.07 mm~(-1) and μ_s' ranged from 1.1 to 2 mm~(-1). These results show that this new 2D-3D hybrid algorithm consistently outperform the 2D-2D or 3D-3D counterparts.
机译:我们已经开发了一种有效的Levenberg-Marquardt迭代算法,该算法利用了三维场测量和二维光学特性重建方案。该技术在3D正向计算中利用了对光分布的准确估计,并在2D反演中减小了问题的大小并减少了计算时间。在提高算法效率和准确性方面的重要进展包括:使用迭代通用最小残差法(GMRES)来计算现场解,将双重网格方案和伴随方法应用于Jacobian构造以及实施归一化方案以减少吸收分散的相声。计算包含单个吸收异常和单个散射异常的立方体模型的合成测量数据。该模型的背景为μ_a= 0.03mm〜(-1),μ_s'= 1.4mm〜(-1)。吸收和散射异常具有μ_a= 0.06 mm〜(-1)和μ_s'= 2.0 mm〜(-1)。每个切片使用五个光源和72个检测器。典型的人前列腺由6片组成。重建图像成功地恢复了具有良好定位的两个异常。还提供了来自组织模拟体模的实验数据。根据协议,在进行光动力治疗之前进行了临床DOT成像。初步结果表明,重建的前列腺μa在0.025和0.07 mm〜(-1)之间变化,μ_s'在1.1至2 mm〜(-1)范围内。这些结果表明,这种新的2D-3D混合算法始终优于2D-2D或3D-3D。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号