DETERMINATION OF ELECTRODE FALLS IN A MODEL LAMP

机译:模型灯中电极落的测定

获取原文
获取原文并翻译 | 示例

摘要

This work is part of investigations aiming at "Fundamental characterization of electrodes far high pressure discharge lamps with time-variant energy input". For several years in Bochum a model lamp has been used to investigate electrodes for HID lamps. So far investigations were focused on cathodes of DC argon arcs. Now as we proceed to the AC operation mode, the processes at the anode and especially the anode fall gain more and more importance. It plays a particular role for the heat balance of the electrode and therefore has a strong influence also on its cathodic phase. In analogy to our previous works concerning cathode falls the DC anode fall is determined by two independent methods: temperature and probe measurements.
机译:这项工作是针对“具有时变能量输入的极高压放电灯的电极的基本特性”研究的一部分。在波鸿(Bochum)几年来,一种模型灯已用于研究HID灯的电极。迄今为止,研究集中在直流氩弧的阴极上。现在,当我们进入交流工作模式时,阳极尤其是阳极跌落的过程变得越来越重要。它对于电极的热平衡起着特殊的作用,因此对阴极相也有很大的影响。与我们先前关于阴极跌落的工作类似,直流阳极跌落是通过两种独立的方法确定的:温度和探针测量。