In order to study the effect of water mist on fire smoke disorder and sinking in road tunnels, it is studied that the influence of water mist particle size on the thickness and temperature distribution and carbon monoxide concentration distribution of fire smoke in the absence of ventilation and longitudinal ventilation. The study is conducted on the road tunnel fire smoke migration characteristics research experiment system. And then preliminary analysis of coupling effect of water mist and ventilation is carried on. The result shows that the release of water mist can make the smoke layer thickening and sinking. The particle size has significant effect on thickness of smoke layer and distribution of temperature, but has less influence on the concentration of CO.
机译:为了研究水雾对火灾烟雾紊乱和道路隧道下沉的影响,研究了水雾粒度对厚度和温度分布的影响,烟雾烟雾的厚度和通风中的含量纵向通风。该研究在路线隧道火灾迁移特征研究实验系统进行。然后进行了水雾和通风耦合效应的初步分析。结果表明,水雾的释放可以使烟雾层加厚和下沉。粒度对烟雾层的厚度和温度分布具有显着影响,但对CO浓度的影响较小。