To establish traceability for high-current measurements, comparison tests of high-current shunts in high-power laboratories have been performed with short-circuit testing liaison (STL) reference shunts since 2005. The concept of the project involves providing only STL traceable shunts and leaving the remaining components needed to form a complete reference-measuring system to the laboratories themselves. Two STL reference shunts (hereinafter called reference shunts) were manufactured, one of which was used in Asia and the other in Europe and Africa. The reference shunts exhibit an rms value of 140 kA symmetrical current, and an asymmetrical peak current of 350 kA. The first round of the comparison tests finished in 2009, and the second round started in 2012. Before starting the second round of comparison tests, the two reference shunts were compared at the CRIEPI high-power testing laboratory in Japan in October 2011. The test results of the inter-comparison tests showed that the two reference shunts qualified as references. From 2012 to 2018, nineteen laboratories in Asia and North America attended comparison tests using the reference shunt for Asia and provided their test data for this paper. In this paper, we describe the comparison test results of shunts in high-power laboratories in Asia and North America in the second round. The test results showed that the shunts tested for the comparison tests performed well and most of the differences in the scale factor with the power frequency current between the reference shunt and those tested in participating laboratories were small.
机译:为了建立用于高电流测量的可追溯性,从2005年以来,已经使用短路测试联络(STL)参考分流进行了高电流实验室中的高电流分流器的比较测试。该项目的概念涉及仅提供STL可追踪分流器和留下剩余的组件需要为实验室本身形成完整的参考测量系统。制造了两种STL参考分流器(以下称为参考分流器),其中一项在亚洲和非洲在亚洲使用。参考分流表现出140ka对称电流的RMS值,以及350 ka的不对称峰值电流。第一轮比较试验于2009年完成,第二轮始于2012年。在开始第二轮比较试验之前,在2011年10月在日本的Criepi高功率测试实验室比较了两种参考分流。测试相互比较的结果表明,两个参考分流分流称为参考文献。从2012年到2018年,亚洲和北美的19个实验室参加了使用参考亚洲分流的比较测试,并为此论文提供了测试数据。在本文中,我们在第二轮中描述了亚洲和北美高功率实验室分流的比较测试结果。测试结果表明,对比较试验进行的分流器进行了良好的表现良好,并且在参考分流器之间的功率频率电流和参与实验室测试的那些具有功率频率电流的大部分差异很小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号