The present paper proposes a methodology to characterize the modal damping ratio as a function of frequency in vibrating systems, with a focus on gas turbine combustion chambers. Proposed methodology correlates the modal damping ratio to the system modal eigenfrequencies, accurately considering the damping physical effects on the system dynamics and goes beyond the standard proportional damping hypothesis and similar techniques present in the literature. The methodology has been compared under free-free conditions with standard damping ratio laws that can be found in the literature and which may lead sometimes to an overestimation of the real damping ratio values. Experimental data obtained through dedicated ping tests performed on two components of an industrial gas turbine annular combustion chamber have been used for the methodology validation: comparison between simulated and experimental results seems to be encouraging and the proposed methodology for modal damping ratio characterization turns out to be better, with respect to the standard ones, in reproducing not only the experimentally estimated damping law (as a function of the frequency), but also the typical Force Response Functions (FRFs) of the considered vibrating systems. Finally, since the adopted procedure is numerically efficient and based only on low cost experimental techniques, it can be used for describing modal damping in vibrating systems since the early phases of the design, by increasing the design accuracy and reducing times and costs.
机译:本文提出了一种方法来表征模型阻尼比作为振动系统中频率的函数,具有焦点燃气轮机燃烧室。提出的方法与系统模态特征频官的模态阻尼比与系统动态的阻尼物理效应进行了相关性,超出了文献中存在的标准比例阻尼假设和类似技术。该方法在具有可自由条件下进行了比较,标准阻尼比例可以在文献中找到,并且有时会导致高估真实阻尼比值。通过在工业燃气轮机环形燃烧室的两个部件上进行的专用Ping测试获得的实验数据已经用于方法验证:模拟和实验结果之间的比较似乎是令人鼓舞的,并且建议的模态阻尼比表征的方法变得令人鼓舞对于标准的,更好地,在不仅在经过实验估计的阻尼法(作为频率的函数)中,还可以更好地再现振动系统的典型力响应函数(FRF)。最后,由于采用的程序在数值上有效并且仅基于低成本的实验技术,因此可以用于描述自设计的早期阶段以来,描述振动系统中的模态阻尼,通过提高设计精度和减少时间和成本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号