The effects of mainstream flow velocity, density ratio (DR), and coolant-to-mainstream mass flow ratio (MFR) were investigated on a vane endwall in a transonic, annular cascade. A blow down facility consisting of five vanes was used. The film cooling effectiveness was measured using binary pressure sensitive paint (BPSP). The mainstream flow was set using isentropic exit Mach numbers of 0.7 and 0.9. The coolant-to-mainstream density ratio varied from 1.0 to 2.0. The coolant to mainstream MFR varied from 0.75% to 1.25%. The endwall was cooled by eighteen discrete holes located upstream of the vane passage to provide cooling to the upstream half of the endwall. Due to the curvature of the vane endwall, the upstream holes provided uniform coverage entering the endwall passage. The coverage was effective leading to the throat of the passage, where the downstream holes could provide additional protection. Increasing the coolant flowrate increased the effectiveness provided by the film cooling holes. Increasing the density of the coolant increases the effectiveness on the endwall while enhancing the lateral spread of the coolant. Finally, increasing the velocity of the mainstream while holding the MFR constant also yields increased protection on the endwall. Over the range of flow conditions considered in this study, the binary pressure sensitive paint proved to be a valuable tool for obtaining detailed pressure and film effectiveness distributions.
机译:在跨音环形级联的叶片端壁上研究了主流流速,密度比(DR)和冷却剂对主流质量流量比(MFR)的影响。使用由五个叶片组成的吹风机。使用二元压力敏感涂料(BPSP)测量膜冷却效果。使用0.7和0.9的等熵退出马赫数设定主流流动。冷却剂到主流密度比率从1.0到2.0变化。将冷却剂主流MFR变化为0.75%至1.25%。通过位于叶片通道上游的十八个离散孔冷却端壁,以提供冷却到端壁的上游半部。由于叶片端壁的曲率,上游孔提供了均匀的覆盖,进入端壁通道。覆盖率有效导致通道的喉部,下游孔可以提供额外的保护。增加冷却剂流量增加了薄膜冷却孔提供的有效性。增加冷却剂的密度增加了端壁上的有效性,同时增强了冷却剂的横向扩散。最后,在保持MFR恒定的同时增加主流的速度也产生了增加的端壁的保护。在本研究中考虑的流动条件范围内,二元压力敏感涂料被证明是获得详细压力和薄膜效果分布的有价值的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号