首页> 外文会议>IEEE International Symposium on Physical and Failure Analysis of Integrated Circuits >An Efficient and Non-destructive Grounding Method for Passive Voltage Contrast Fault Isolation
【24h】

An Efficient and Non-destructive Grounding Method for Passive Voltage Contrast Fault Isolation

机译:一种有效且无损接地方法,用于被动电压对比度故障隔离

获取原文

摘要

Voltage contrast is widely utilized as a localization method for opens (or shorts) on circuits and test structures. Conventional Passive Voltage Contrast grounding methods are mainly grouped into two types. First method, laser ablation forming a hole down to substrate and connecting the substrate with grounding pad using Focused Ion Beam (FIB) Pt deposition. Second method, FIB ion mill a hole down to substrate and then connect substrate with grounding pad using FIB Pt deposition. New grounding method using OmniProbe micromanipulator introduced to eliminate contamination due to laser ablation, re-deposition during FIB milling and it is non-destructive with the ease to switch grounding pad as needed.
机译:电压对比度广泛用于在电路和测试结构上打开(或短路)的定位方法。传统的被动电压对比接地方法主要分为两种类型。第一方法,激光消融将孔的孔形成为基板并使用聚焦离子束(FIB)PT沉积与接地垫将基板连接。第二种方法,FIB离子磨出孔向下底物,然后使用FIB PT沉积将基板连接到接地垫。使用Omniprobe微操纵器引入的新接地方法来消除由于激光烧蚀引起的污染,在FIB铣削期间再沉积,并且由于需要而易于关闭接地垫。