首页> 外文会议>Chinese intelligent systems conference >Uniform Demagnetization Fault Diagnosis in Permanent Magnet Synchronous Motors Based on the Back-EMF Gyration Radius
【24h】

Uniform Demagnetization Fault Diagnosis in Permanent Magnet Synchronous Motors Based on the Back-EMF Gyration Radius

机译:基于反效率循环半径的永磁同步电机均匀的退磁故障诊断

获取原文

摘要

Uniform demagnetization fault is troublesome, because it can profoundly impact the overall performance of permanent magnet synchronous motors (PMSMs). In this paper, the back electromotive force (Back-EMF) gyration radius method is used to diagnose the uniform demagnetization fault of the PMSM. First, a model of the Back-EMF gyration radius is established, which using time delay embedding (TDE) technology. Second, the Back-EMF gyration radius of PMSM with different operating speeds and different faults is calculated, and the rate of change of the back-EMF gyration radius is taken as the uniform demagnetization fault factor which is used to detect uniform demagnetization fault and fault degree. Finally, the simulation results show that proposed method can achieve PMSM uniform demagnetization fault detection and degree evaluation with a small amount of calculation.
机译:均匀的退磁故障是麻烦的,因为它可以深刻地影响永磁同步电动机的整体性能(PMSMS)。在本文中,用于诊断PMSM的均匀退磁故障的背部电动势(反EMF)。首先,建立了反态循环半径的模型,使用时间延迟嵌入(TDE)技术。其次,计算具有不同操作速度和不同故障的PMSM的后效率循环半径,并将反效率转换半径的变化率作为均匀的退磁故障因子,用于检测均匀的退磁故障和故障程度。最后,仿真结果表明,提出的方法可以通过少量计算来实现PMSM均匀的退磁故障检测和度评价。