The technology of injecting micro-sized proppant particles along with fracturing fluid is proposed to improve the conductivity of naturally fracture systems (e.g., cleats, natural fractures) in stress sensitive reservoirs, by placing graded particles in a larger, preserved stimulated reservoir volume around the induced hydraulical fracture. One of the main parameters determining the efficiency of the proposed technology is the concentration of placed proppant particles in the fracture systems. A laboratory study has been conducted to evaluate the effect of placed proppant concentration on coal permeability enhancement using a one-dimensional linear injection of micro-sized proppant into coal core and varying effective stress. Permeability values are measured for different concentrations of placed particles as a function of effective stress. The results show that there is an optimum concentration of placed particles for which the cleat system permeability reaches a maximum and permeability enhancement is more sensitive to concentration of placed proppant at higher than lower effective stress. The experimental results show maximum permeability enhancement of about 20% for an optimum concentration of placed particles at 490 psi effective stress. Permeability enhancement by 3.2 folds is observed at elevated effective stress of 950 psi. Finally, the paper proposes a field application strategy to apply graded particle injection in field case study.
机译:提出了通过将碎片颗粒放置在较大,保存的施用储存量的较大刺激的储存量的情况下,提出了在压力敏感储层中自然断裂体系(例如,夹层,自然骨折)的天然骨折系统(例如,夹层,自然骨折)的导电性。诱导液压骨折。确定所提出的技术效率的主要参数之一是骨折系统中放置的支撑剂颗粒的浓度。已经进行了实验室研究,以评估Proppant浓度对煤渗透性提高的效果,使用一维线性注射微型支撑剂进入煤芯并改变有效应力。根据有效应力的函数,测量渗透率值以针对不同浓度的放置颗粒测量。结果表明,放置的颗粒具有最佳浓度,其中夹板系统渗透率达到最大,渗透性增强对放置的支撑剂的浓度更敏感,高于较低的有效应力。实验结果表明,在490psi有效应力下放置颗粒的最佳浓度,最大渗透性提高约20%。在950psi的有效应力高的有效应力下观察到渗透性提高3.2折。最后,本文提出了一种现场应用策略,用于在现场案例研究中应用分级粒子注射。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号