Development of energy-resolved photon-counting mammography with a cadmium telluride series detector to reduce radiation exposure and increase contrast-to-noise ratio using the high-energy X-rays

机译:用碲化镉串联探测器的能量分辨光子计数乳房X线照相术的发展,以减少辐射曝光,并使用高能X射线提高对比度率

获取原文

摘要

A new energy-resolved photon-counting mammography (ERPCM) device with a cadmium telluride (CdTe) series detector (JOB Corporation, Japan) is currently being developed. The CdTe series detector can detect higher-energy photons with high sensitivity, enabling the use of high-energy X-rays for imaging. Our previous research, in which we compared ERPCM using high-energy X-rays (tube voltage 50 kV) with general mammography using low-energy X-rays (tube voltage about 30 kV), reported that ERPCM had a higher CNR (contrast-to-noise ratio) than general mammography. The purpose of this study was to examine the magnitude of the CNR using a simulation and ERPCM; especially we would like to examine the CNR when the tube voltage of higher than 50 kV was adopted. In the comparison of the CNRs, It was necessary to pay attention to equalizing the average glandular dose (AGD). Using the simulation and ERPCM, we compared the CNR between images taken at 50 kV and 75 kV under a constant AGD. The simulation phantom was composed of 50% mammary gland and 50% adipose tissue, and contained tumor regions. The thickness of the simulation phantom was varied. We put an acrylic plate (1 mm thickness) on an RMI-156 phantom. Furthermore, we placed the thicker acrylic plate (10,20, 30,40 mm) on the 156 phantom and 1 mm-thick acrylic plate to simulate thicker breast. Based on the results from the simulation, in the phantom thickness of 80 mm, the CNR of image taken by 75kV got extremely closer to that taken by 50kV. The advantage of the image taken at 75 kV for the thicker breast was also confirmed in ERPCM.
机译:目前正在开发一种具有碲化镉(CDTE)序列探测器(Job Corporation,Japan)的新能量分辨的光子计数乳房X线摄影(ERPCM)装置。 CDTE系列检测器可以检测具有高灵敏度的更高能量的光子,使得能够使用高能X射线进行成像。我们以前的研究,其中我们使用低能量X射线(管电压约30kV)使用高能X射线(管电压50kV)使用高能X射线(管电压50kV)进行比较ERPCM(管电压约30kV),报道ERPCM具有更高的CNR(对比度 - 噪声比)比一般乳房X线摄影。本研究的目的是使用模拟和ERPCM来检查CNR的大小;特别是我们想在采用高于50kV的管电压时检查CNR。在CNR的比较中,有必要注意平均腺剂量(AGD)。使用模拟和ERPCM,我们将在恒定的AGD下以50kV和75 kV拍摄的图像之间的CNR进行比较。模拟幻影由50%乳腺和50%脂肪组织组成,并含有肿瘤区域。模拟模拟的厚度变化。我们将丙烯酸板(1毫米厚)放在RMI-156幻影上。此外,我们将较厚的丙烯酸板(10,20,30,40mm)放在156个模型和1mm厚的丙烯酸板上以模拟较厚的乳房。基于模拟的结果,在80 mm的幻像厚度下,75kV拍摄的图像的CNR极其更接近50kV。在ERPCM中也证实了在75 kV下拍摄的图像的优点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号