首页> 外文会议>Electrical Overstress/Electrostatic Discharge Symposium >Electrostatic discharges from charged particles approaching a grounded surface
【24h】

Electrostatic discharges from charged particles approaching a grounded surface

机译:从接地表面接近带电粒子的静电放电

获取原文

摘要

A program based on the boundary element method enabled accurate computation of the electric field in the gap between a conductive sphere of given charge and a grounded plate. The information on field distribution represented the input data of another program which estimated the dielectric strength of that gap in air at atmospheric pressure. In this way, it was possible to determine the critical conditions (charge, gap length) in which a discharge occurs between spherical objects of various sizes and a grounded surface. In all the situations under study, the computed data were in good agreement with the experimental results.
机译:基于边界元方法的程序使能够精确地计算给给定电荷和接地板的导电球体之间的间隙中的电场。关于现场分布的信息表示另一节目的输入数据,其估计在大气压下空气中该间隙的介电强度。以这种方式,可以确定临界条件(电荷,间隙长度),其中在各种尺寸的球形物体和接地表面之间发生放电。在研究的所有情况下,计算数据与实验结果吻合良好。