Impulse Voltage-based Test Method for Identifying the Stator Insulation Component with PD Activity for Low Voltage AC Motors

机译:基于脉冲电压的测试方法,用于识别具有低压交流电动机的PD活性的定子绝缘部件

获取原文

摘要

IEC 60034-18-41 has been developed as a standard acceptance test to ensure partial discharge (PD)-free operation for improving the reliability of low voltage (LV) variable frequency drive (VFD) motors. Although the test can verify whether PD exists in the stator for a voltage surge with predetermined magnitude and risetime, the information on where PD activity is occurring in the stator insulation is not clearly given. In this paper, a method based on variable risetime surge voltage testing is proposed for identifying the component of the stator insulation system where PD occurs in LV random wound motor stators (turn, phase, or ground insulation). This information can be used for increasing the PD inception voltage for improving the reliability of the motor through insulation system design/manufacturing. The test is implemented with a 4.5 kV variable risetime surge generator prototype. 4 LV ac motors are tested to show where PD is likely to occur in commercial LV motors.
机译:IEC 60034-18-41已被开发为标准验收测试,以确保部分放电(PD) - 免费操作,用于提高低压(LV)变频器(VFD)电机的可靠性。尽管测试可以验证PD是否存在于具有预定幅度和提升时间的电压浪涌的定子中,但是没有清楚地给出关于在定子绝缘体中发生PD活性的信息的信息。在本文中,提出了一种基于可变超细电涌电压测试的方法,用于识别定子绝缘系统的组件,其中PD在LV随机卷绕电机定子(转动,相位或地绝缘)中发生。该信息可用于增加通过绝缘系统设计/制造来提高电动机的可靠性的PD初始电压。该测试用4.5 kV可变立柱浪涌发生器原型实现。测试4 LV AC电动机以显示在商业LV电机中可能发生PD的位置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号