首页> 外文期刊>Dielectrics and Electrical Insulation, IEEE Transactions on >Experimental evaluation of using the surge PD test as a predictive maintenance tool for monitoring turn insulation quality in random wound AC motor stator windings
【24h】

Experimental evaluation of using the surge PD test as a predictive maintenance tool for monitoring turn insulation quality in random wound AC motor stator windings

机译:使用浪涌PD测试作为预测性维护工具来监控随机缠绕的交流电机定子绕组的匝绝缘质量的实验评估

获取原文
获取原文并翻译 | 示例
           

摘要

Turn insulation degradation is one of the major root causes of stator insulation failure leading to motor breakdown. The surge test is the only test available for testing the integrity of turn insulation; however, it is a high voltage pass/fail test that provides an indication only if an arc is instigated between the turns of weakened turn insulation, and therefore does not provide information regarding remaining lifetime. The surge PD test measures the partial discharge (PD) activity under surge excitation, and is used to date for assuring that voltage source PWM inverter-fed motors (IEC 60034-18-41 type I) are PDfree. In this paper, the potential of using the surge PD test as a predictive maintenance tool for turn insulation quality assessment is evaluated. Under the expectation that increasing PD activity in the voids formed by insulation degradation may be detectable before turn insulation failure, the test is performed periodically under accelerated thermal degradation on 6 windings. It is shown that change in the PD inception voltage under the surge PD test can be clearly observed before any other insulation test indicator. The results suggest that the surge PD test can be used for monitoring the condition of turn insulation for providing an early indication of stator insulation problems without the risk of puncturing turn insulation.
机译:匝间绝缘性能下降是导致电机故障的定子绝缘故障的主要原因之一。浪涌测试是唯一可用于测试匝间绝缘完整性的测试。但是,只有通过弱化的匝绝缘层之间的电弧产生电弧时,高压通过/不通过测试才提供指示,因此不提供有关剩余寿命的信息。浪涌PD测试可测量浪涌激励下的局部放电(PD)活动,迄今为止已用于确保电压源PWM逆变器供电的电机(IEC 60034-18-41 I型)不含PD。在本文中,评估了将浪涌PD测试作为预测维护工具进行匝间绝缘质量评估的潜力。预期在匝间绝缘失效之前可以检测到由绝缘退化形成的空隙中的PD活性增加,因此在6个绕组的加速热退化下定期进行测试。结果表明,在任何其他绝缘测试指标之前,可以清楚地观察到电涌PD测试下PD起始电压的变化。结果表明,浪涌PD测试可用于监视匝间绝缘的状况,以提供定子绝缘问题的早期指示,而不会刺穿匝间绝缘。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有