Impulse Voltage-based Test Method for Identifying the Stator Insulation Component with PD Activity for Low Voltage AC Motors

机译:基于脉冲电压的测试方法,用于识别低压交流电机的具有PD活动的定子绝缘组件

获取原文

摘要

IEC 60034-18-41 has been developed as a standard acceptance test to ensure partial discharge (PD)-free operation for improving the reliability of low voltage (LV) variable frequency drive (VFD) motors. Although the test can verify whether PD exists in the stator for a voltage surge with predetermined magnitude and risetime, the information on where PD activity is occurring in the stator insulation is not clearly given. In this paper, a method based on variable risetime surge voltage testing is proposed for identifying the component of the stator insulation system where PD occurs in LV random wound motor stators (turn, phase, or ground insulation). This information can be used for increasing the PD inception voltage for improving the reliability of the motor through insulation system design/manufacturing. The test is implemented with a 4.5 kV variable risetime surge generator prototype. 4 LV ac motors are tested to show where PD is likely to occur in commercial LV motors.
机译:IEC 60034-18-41已作为标准验收测试而开发,以确保无局部放电(PD)的运行,从而提高了低压(LV)变频驱动(VFD)电动机的可靠性。尽管该测试可以验证在预定大小和上升时间的电压浪涌中定子中是否存在PD,但并未明确给出在定子绝缘中发生PD活动的位置的信息。在本文中,提出了一种基于可变上升时间浪涌电压测试的方法,用于识别定子绝缘系统的组件,在该组件中,PD出现在LV随机绕线电动机定子中(匝数,相位或接地绝缘)。此信息可用于增加PD起始电压,以通过绝缘系统设计/制造来提高电动机的可靠性。该测试使用4.5 kV可变上升时间电涌发生器原型进行。测试了4台LV交流电动机,以显示商用LV电动机中可能出现PD的位置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号