摘要

The study presents the surface tension measurement data of HFO-1123 and HFO-1234ze(E) with global warming potential (GWP) of less than 1 and of binary mixtures HFO-1123/HFC-32 and HFO-1234ze(E)/HFC-32. The capillary constant and surface tension of the fluids are measured across temperatures in a range of 267 K to 307 K with a differential capillary rise with a propagated uncertainty of ±0.23 mN m~(-1). Among the selected predicting methods, the correlations of DiNicola et al. (2018) exhibit the best agreement to the measured surface tension of both HFO-1123 and HFO-1234ze(E). In order to predict the surface tension HFO-1123/HFC-32 and HFO-1234ze(E)/HFC-32, empirical correlations are proposed based on the measured data.
机译:该研究介绍了HFO-1123和HFO-1234ze(E)的表面张力测量数据,具有小于1和二元混合物HFO-1123 / HFC-32和HFO-1234ZE(E)/ HFC的全球变暖电位(GWP) -32。流体的毛细管常数和表面张力在267k至307k的温度下测量,差异毛细血管升高,其传播不确定度为±0.23mn m〜(-1)。在所选预测方法中,Dinicola等人的相关性。 (2018)表现出HFO-1123和HFO-1234ZE(E)的测量表面张力的最佳协议。为了预测表面张力HFO-1123 / HFC-32和HFO-1234ze(E)/ HFC-32,基于测量数据提出经验相关性。