Carborundum of the sample is determined by potassium fluosilicate titration.The Al2O3-SiC-C brick sample was melted with KOH and KNO3 in the nickel-rucible.Through the experiment,choosed the best melt condition.The melting temperature was 700°C and melting time was 15 min.The method can avoid on fire and explosion during the melt of the sample.At the same time.it diminished the damage of the nickel-rucible and it was easy to soak out.A self-made filtration device will replaced of ordinary filtration bottles,filtration part of the glass was replaced by plastic,only needed 1/4 filter paper (filter paper diameter approximately is 40 mm),easy to wash and neutralization,greatly reduced the detection time.Measuring results conformed with the results of the national standard method.Relative standard deviation of determination result was less than 5%.
机译:样品的Carborundum由氟硅酸钾滴定决定。Al2O3-SiC-C砖样品用KOH和KNO3熔化,在镍锰中熔化。采用实验,选择最佳熔体条件。熔化温度为700°C和熔化时间是15分钟。该方法可以避免在样品熔体期间避免火灾和爆炸。同时缩短镍锰的损坏,并且易于浸泡。将自制过滤装置更换。更换普通过滤瓶中,玻璃的过滤部分被塑料取代,只需要1/4滤纸(滤纸直径约为40毫米),易于清洗和中和,大大降低了检测时间。测量结果符合结果国家标准方法。测定结果的标准偏差小于5%。