This paper presents the experimental test results for the buckling capacity of tubular columns exposed to simulated unsymmetrical patch corrosion damage. These tests were performed to investigate how the results of these experiments compare with the capacities obtained for the formulae provided in the 2004 revision of NORSOK N-004. Formulae for patch corroded tubular columns are needed in standards and as such it is unfortunate that these formulae are removed from the present revision of the NORSOK N-004 standard. Prior to suggesting introducing these previous formulae in standards, experimental tests to confirm good correlation between experiments and formulae are needed. The tests performed in this work are presented in this paper for 100% (intact columns), 69%, 34% and 0% remaining wall thickness in the patch.
机译:本文提出了暴露于模拟的非对称贴片腐蚀损坏的管状柱的屈曲能力的实验测试结果。 进行这些测试以研究这些实验的结果如何与Norsok N-004的2004年修订中提供的公式所获得的能力相比。 贴片腐蚀管柱的公式是必需的,因此不幸的是,这些公式从本文的Norsok N-004标准的修订中取出。 在建议在标准中引入这些先前的公式之前,需要实验测试以确认实验与公式之间的良好相关性。 本文在本文中进行的测试在本文中呈现为100%(完整塔),69%,34%和0%在贴片中剩余壁厚。