In the present paper, a centralized control method of the tap configuration for step-voltage regulators (SVRs) is proposed. First, the problem will be formulated: The power flow equations and the objective function with its constraints will be described for the studied system. Two different objective functions are defined for comparison purposes: On the one hand, the objective will be minimizing the deviations of voltages with respect to their rated values. On the other hand, the minimized voltage scenario is considered. These two cases are compared also to the case base in which there is no regulation. Aspects such as power injected to the grid, power losses and degree of unbalance are analyzed. Focusing on residential feeders, a complete 24-hour span will let us simulate several different load conditions. Moreover, by utilizing a general load model, instead of the constant power model (PQ), and by applying an accurate load demand prediction, more realistic results are achieved. The case studies are implemented in a modified version of the IEEE 123 Node Test Feeder, which includes additional and rearranged regulators.
机译:在本文中,提出了一种用于阶梯式稳压器(SVRS)的抽头配置的集中控制方法。首先,将制定问题:将对研究系统描述电流方程和其约束的目标函数。为比较目的定义了两种不同的客观函数:一方面,目标将最小化电压相对于其额定值的偏差。另一方面,考虑最小化的电压方案。将这两种情况进行比较到没有规则的情况下。分析了诸如注入电网的功率,功率损耗和不平衡程度的方面。专注于住宅饲养者,一个完整的24小时跨度将让我们模拟几种不同的负载条件。此外,通过利用一般负载模型,代替恒定功率模型(PQ),并且通过应用准确的负载需求预测,实现了更现实的结果。案例研究在IEEE 123节点测试馈线的修改版本中实现,其包括附加和重排的调节器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号