Email from an industry colleague "Li-ion community would substantially benefit from the development of a toolset that evaluates ..." Location of internal short within the cell Rate of shorting resistance change with time Variation in cell thermal/electrical conductivity during the shorting Location of faulted cell within module/pack Influence of system cooling status Initial system temperature Electrical power flow between faulted cell and other cells Temperature of the pack surroundings.