Laboratory effluents contain complicated component with the characteristics of incertitude, diversification and poor recurrence. The ordinary wastewater treatment method is difficult to deal with this problem. In this study, ultra-filtration membrane was carried out to experiment at different condition of PH, pressure, concentration of substances, ionic strength, respectively. The result shows that ultra-filtration membrane has good rejections for heavy metals, sulphide, volatile hydroxybenzene, aniline compound and fluoride in rational PH value. The retentions of ultra-filtration membrane for substance not only are related to physical separation, but also related to PH value and ionic strength. The retention of ultra-filtration membrane for different species can be interpreted by taking into account the interaction between solute-solute and solute-membrane. Therefore, ultra-filtration membrane will be applied to a broad range.
机译:实验室流出物含有复杂的组成部分,其特征是健全,多样化和复发不良。 普通的废水处理方法难以解决这个问题。 在该研究中,进行超过滤膜以在不同的pH,压力,物质浓度,离子强度的不同条件下进行实验。 结果表明,超过滤膜对重金属,硫化物,挥发性羟基苯,苯胺化合物和合理pH值中的氟化物具有良好的抑制。 用于物质的超过滤膜的保留不仅与物理分离有关,还与pH值和离子强度有关。 通过考虑溶质溶质和溶质膜之间的相互作用,可以解释用于不同物种的超滤膜的保留。 因此,超过滤膜将施加到宽范围内。