首页> 外文会议>The Progress of Green Oxidation/Reduction Technologies >Study on Treatment for Laboratory Effluents by Ultra-filtration Membrane
【24h】

Study on Treatment for Laboratory Effluents by Ultra-filtration Membrane

机译:超滤膜处理实验室废水的研究

获取原文
获取原文并翻译 | 示例

摘要

Laboratory effluents contain complicated component with the characteristics of incertitude, diversification and poor recurrence. The ordinary wastewater treatment method is difficult to deal with this problem. In this study, ultra-filtration membrane was carried out to experiment at different condition of PH, pressure, concentration of substances, ionic strength, respectively. The result shows that ultra-filtration membrane has good rejections for heavy metals, sulphide, volatile hydroxybenzene, aniline compound and fluoride in rational PH value. The retentions of ultra-filtration membrane for substance not only are related to physical separation, but also related to PH value and ionic strength. The retention of ultra-filtration membrane for different species can be interpreted by taking into account the interaction between solute-solute and solute-membrane. Therefore, ultra-filtration membrane will be applied to a broad range.
机译:实验室废水成分复杂,不确定,重复性差等特点。普通的废水处理方法很难解决这个问题。本研究采用超滤膜分别在不同的PH,压力,物质浓度,离子强度条件下进行实验。结果表明,超滤膜在合理的PH值下对重金属,硫化物,挥发性羟基苯,苯胺化合物和氟化物具有良好的截留率。超滤膜对物质的保留不仅与物理分离有关,而且与PH值和离子强度有关。通过考虑溶质-溶质和溶质-膜之间的相互作用,可以解释不同种类的超滤膜的保留率。因此,超滤膜将被广泛应用。