Tenova Pyromet designed, supplied, and commissioned a 12 MVA circular electric furnace for Sibanye-Stillwater (previously Lonmin) in South Africa. The furnace has been operating successfully since its commissioning in 2012. The paper provides an overview of the furnace performance and campaign life history, and explores the innovative design concepts and improvements implemented. Of particular interest is the use of a novel sidewall lining design that utilizes indirect cooling to remove excess heat from the matte/slag tidal zone without the need to use water-cooled copper. Furthermore, the performance of Tenova's Soderberg electrode column designed for base metal applications, limiting water use above the furnace, is discussed. In addition, the joint development and performance of an uncooled cast iron matte taphole faceplate is presented. Potential future design innovations to further improve smelter operating safety are discussed.
机译:Tenova Pyromet设计,供应,并为南非的Sibanye-stordwater(以前Lonmin)设计了12个MVA圆形电炉。 自2012年委托以来,炉子一直成功运营。本文概述了炉子绩效和竞选生活史,并探讨了实施的创新设计概念和改进。 特别令人兴趣的是使用一种新颖的侧壁衬里设计,该设计利用间接冷却去除来自遮光器/炉渣潮汐区的过量热,而无需使用水冷铜。 此外,讨论了为基础金属应用设计的Tenova的Soderberg电极柱的性能,限制炉子上方的用水。 此外,提出了一个未处理的铸铁哑光塔尔面板的联合开发和性能。 讨论了进一步改善冶炼厂经营安全的潜在未来的设计创新。