首页> 外文会议>Conference on Frontier Academic Forum of Electrical Engineering >Radiation Magnetic Field Research of Primary/Secondary Fusion Switch Cabinet Based on Frequency Scaling Approach
【24h】

Radiation Magnetic Field Research of Primary/Secondary Fusion Switch Cabinet Based on Frequency Scaling Approach

机译:基于频率标度法的一次/二次熔合开关柜辐射磁场研究

获取原文

摘要

According to incomplete statistics, due to various electromagnetic interference, the phenomenon of signal distortion and even the misoperation of internal equipment often appears in the primary/secondary fusion switch cabinet. Firstly, the characteristics of arc extinction in the switch cabinet was analyzed in this paper, and used time-varying resistance to simulate the arc circuit. Then, the time domain finite integral method is selected to calculate the radiation magnetic field of the arc of the switch cabinet. The frequency scaling approach is used to process the interference signal and speed up the simulation. The results show that under the proposed transient interference, the instantaneous magnetic field intensity near the electronic components such as transformer is extremely high, which exceeds the specified value of relevant standards, and may cause equipment failure in actual operation. The frequency scaling approach can calculate the radiation within a certain accuracy.
机译:据不完全统计,由于各种电磁干扰,一次/二次熔合开关柜内经常出现信号失真甚至内部设备误操作的现象。本文首先分析了开关柜内的电弧熄灭特性,并用时变电阻法对电弧回路进行了仿真。然后,采用时域有限积分法计算开关柜电弧的辐射磁场。采用频率缩放方法对干扰信号进行处理,加快了仿真速度。结果表明,在提出的瞬态干扰下,变压器等电子元件附近的瞬态磁场强度极高,超过了相关标准的规定值,在实际运行中可能导致设备故障。频率标度法可以在一定精度内计算辐射。