Application of Micro-Structure Testing in the Analysis of the Cause of Concrete Cracks

机译:微结构测试在混凝土裂缝原因分析中的应用

获取原文

摘要

Scanning electron microscope, differential thermal analysis, thermo-gravimetric analysis, fluorescent analysis and X-ray CT et.al.have become usual means used in the research of concrete material science. This paper proposed a new method to evaluate the causes of cracking of in-situ concrete based on the investigation by using these comprehensive technologies for analysis of micro-structure. The proposed new method is more reliable and objective than the traditional method which is mainly based on experience and chemical analysis. A case investigation using the new method to explore the causes of cracking in a real project was introduced.
机译:扫描电子显微镜,差分热分析,热重分析,荧光分析和X射线CT et.Al.have成为混凝土材料科学研究的常用手段。 本文提出了一种新方法,以评估原位混凝土裂缝的原因,以通过使用这些综合技术分析微结构的研究。 提出的新方法比主要基于经验和化学分析的传统方法更可靠,客观更可靠。 介绍了利用新方法探讨了实际项目中开裂原因的案例调查。