Resonant neutral grounding operation is the most common operation mode of large capacity distribution network. A fault line selection method based on the combination of variational mode decomposition and signal injection is proposed to solve the problem of single-phase grounding fault line selection in distribution network with resonant grounding operation. After a single-phase fault occurs in the distribution network, the signal is injected by the injection signal source through the neutral point. The signals of each outgoing line are sampled for the variational mode decomposition. Intrinsic mode functions are obtained and the energy values are calculated. The relative entropy of energy, which can reflect the subtle difference of signals, is used as the criterion for line selection. The results of simulation show that the method has a high accuracy.
机译:共振中性接地操作是大容量分配网络中最常见的操作模式。 提出了一种基于变分模式分解和信号注射组合的故障线选择方法,以解决具有共振接地操作的分配网络中单相接机故障线选择的问题。 在分配网络中发生单相故障之后,通过注射信号源通过中性点注入信号。 对变分模式分解进行采样每个输出线的信号。 获得了内在模式功能,并计算能量值。 能量的相对熵,它可以反映信号的微妙差异,作为线路选择的标准。 仿真结果表明该方法具有高精度。