首页> 外文会议>Workshop on Synthesis, Characterization and Applications of Inorganic Powders >The Effect of Varying Ferrule Modes on Fracture Resistance of Canines Restored with One-piece Milled Zirconia Post and Core
【24h】

The Effect of Varying Ferrule Modes on Fracture Resistance of Canines Restored with One-piece Milled Zirconia Post and Core

机译:不同套圈改变对犬碎片氧化锆柱恢复犬裂缝抗性的影响

获取原文

摘要

The aim of this invitro study was to evaluate the fracture resistance of endodontically treated canines restored with one-piece milled zirconia post and core in the varying ferrule modes. Fifty recently extracted human maxillary canines were endodontically treated and randomly divided into 5 groups of 10 specimens each. According to the defect degree of ferrule, intact ferrule was classified as group A and served as control, 2 mm ferrule height without buccal ferrule was classified as group B, 2 mm ferrule height without mesial and buccal ferrule was classified as group C, 2 mm ferrule height without mesial, buccal and lingual ferrule was classified as group D, no ferrule preparation was classified as group E. All of the teeth were restored with one-piece milled zirconia post and core, and zirconia crowns. The teeth were prepared to standardized specifications. The restored teeth were loaded to fracture at a 135° angle to their long axis, at a cross-head speed 0.5 mm/min, and the load (N) at failure was recorded. Statistical analysis was performed by SNK pairwise multiple comparisons (α=0.05). The mean fracture resistance of five groups as follows: 1019.30±139.01N for group A, 861.20±105.67N for group B, 833.70±100.56N for group C, 733.20±96.91N for group D, 698.00±99.90N for group E. The fracture resistance of restored teeth between group B and group C, group D and group E had no statistically significant difference(P>0.05). The fracture resistance of the rest pairwise group comparisons had statistically significant difference(P<0.05). Increasing the absence degree of ferrule, it was found that the fracture resistance decrease. The buccal and lingual ferrule were more important than mesial ferrule for enhanced fracture resistance. This in vitro study supports evidence that reserving the buccal and lingual ferrule is a key point to increase the fracture resistance of canines restored with one-piece milled zirconia post and core.
机译:该邀请委员会研究的目的是评估在不同套圈模式中用一体式研磨的氧化锆柱和核心恢复的脊髓治疗的犬的骨折性。五十最近提取的人颌骨犬在脊髓处理并随机分为5组10个标本。根据套圈的缺陷程度,完整的套圈被分类为A组并用作对照,没有颊衣套圈的2mm套圈高度被归类为B组,2mm套圈高度没有薄膜和口腔套圈归类为C组,2 mm没有薄膜的套圈高度被归类为D组D,没有将套圈制剂分类为E组。将所有牙齿恢复为一体式研磨的氧化锆柱和核,氧化锆冠。将牙齿制备成标准化的规格。将恢复的牙齿以135°角的骨折以135°角,在它们的长轴下,在十字速度0.5mm / min,记录故障时的负载(n)。通过SNK成对多次比较进行统计分析(α= 0.05)。五组的平均断裂抗性如下:对于A组,对于B组,861.20±105.67N,C组的8.61.70±100.56N,用于组D组的733.20±96.91N,E组698.00±99.90N。 B组和C组之间恢复牙齿的骨折性耐牙齿无统计学意义(p> 0.05)。其余成对群体比较的裂缝抗性差异有统计学意义(P <0.05)。增加了套圈的缺失程度,发现裂缝抗性降低。口腔和舌套套圈比微囊套圈更重要,以提高骨折抗性。这种体外研究支持证据,证据证明预留颊和舌套圈是增加用一体式研磨的氧化锆柱和核心恢复的犬骨折抗性的关键点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号