首页> 外文会议>Symposium on Design, Test, Integration amp;amp;amp;amp;amp;amp; Packaging of MEMS and MOEMS >Analysis of Thin Film Parylene-Metal-Parylene Device Based on Mechanical Tensile Strength Measurement
【24h】

Analysis of Thin Film Parylene-Metal-Parylene Device Based on Mechanical Tensile Strength Measurement

机译:基于机械拉伸强度测量的薄膜聚对二甲苯 - 金属聚氨酯装置分析

获取原文

摘要

This paper presents an FEM analysis and experiment of parylene-metal-parylene flexible substrate for implantable medical devices. Tensile strength measurement of the parylene-metal-parylene has been carried out and corresponding FEM modeling and simulation has been done to understand its mechanical behaviour. Besides, frequently encountered metal delamination on parylene substrate has been studied based on cohesive zone model of interface between the two materials.
机译:本文介绍了用于植入医疗装置的二甲基金属 - 聚对二甲苯柔性基材的有限元分析和实验。已经进行了聚对二甲苯 - 金属聚对二甲苯的拉伸强度测量,并进行了相应的有限元模拟和模拟以了解其机械行为。此外,已经基于两种材料之间的界面的粘性区模型研究了对二甲苯基质的经常遇到的金属分层。