首页> 外文会议>IEEE Conference on Electrical Insulation and Dielectric Phenomenon >Relationship between Size of Leaked Nucleic Acid of Escherichia coli and Survival Ratio by High Electric Field Pulse Application
【24h】

Relationship between Size of Leaked Nucleic Acid of Escherichia coli and Survival Ratio by High Electric Field Pulse Application

机译:高电场脉冲应用的大肠杆菌泄漏核酸大小与生存率的关系

获取原文
获取外文期刊封面目录资料

摘要

We have been studying the sterilization of bacteria by high electric field pulse. In this paper, we reported the relationship between the size of leaked nucleic acid of Escherichia coli (JM103) and the survival ratio by high electric field pulse application. The sample was NaCl aqueous solution contained E. coli. High electric field pulse (6 kV/mm ~ 10 kV/mm) was applied to the sample at room temperature. As results, at pulse width 600 ns, we could not detect the leakage nucleic acid. At pulse width 60 μs, we could observe the leakage of 2 ~ 3 kbp by 5 kV/mm or more pulse application, and that of 10 kbp by 8 kV/mm or more. At pulse width 120 μs, we could observe the leakage of 2 ~ 3 kbp by 8 kV/mm.
机译:我们一直通过高电场脉冲研究细菌的灭菌。本文报道了大肠杆菌(JM103)泄漏核酸尺寸与高电场脉冲施加的关系。样品是NaCl水溶液含有大肠杆菌。在室温下将高电场脉冲(6kV / mm〜10kV / mm)施加到样品上。结果,在脉冲宽600ns处,我们无法检测漏核酸。在脉冲宽度为60μs时,我们可以观察到2〜3 kbp的泄漏5 kV / mm或更多脉冲施加,10kbp的泄漏为8kv / mm或更大。在脉冲宽度120μs,我们可以观察8 kV / mm的泄漏2〜3 kbp。