Imaging photoplethysmography is a technique through which the morphology of the blood volume pulse can be obtained through non-contact video recordings of exposed skin with superficial vasculature. The acceptance of such a convenient modality for use in everyday applications may well depend upon the availability of consumer-grade imagers that facilitate ease-of-adoption. Multiple imagers have been used previously in concept demonstrations, showing improvements in quality of the extracted blood volume pulse signal. However, the use of multi-imager sensors requires synchronization of the frame exposures between the individual imagers, a capability that has only recently been available without creating custom solutions. In this work, we consider the use of multiple, commercially-available, synchronous imagers for use in imaging photoplethysmography. A commercially-available solution for adopting multi-imager synchronization was analyzed for 21 stationary, seated participants while ground-truth physiological signals were simultaneously measured. A total of three imagers were used, facilitating a comparison between fused data from all three imagers versus data from the single, central imager in the array. The within-subjects design included analyses of pulse rate and pulse signal-to-noise ratio. Using the fused data from the triple-imager array, mean absolute error in pulse rate measurement was reduced to 3.8 as compared to 7.4 beats per minute with the single imager. While this represents an overall improvement in the multi-imager case, it is also noted that these errors are substantially higher than those obtained in comparable studies. We further discuss these results and their implications for using readily-available commercial imaging solutions for imaging photoplethysmography applications.
机译:成像光体积描记是通过它可以通过暴露的皮肤浅表血管系统的非接触式视频记录来获得血容量脉冲的形态的技术。如此便捷的方式使用的接受在日常应用中很可能取决于消费级成像促进易用性,采用的可用性。多个成像器已经在概念示范先前使用的,示出在所抽取的血液体积的脉冲信号的质量的改善。然而,使用多成像传感器需要单独成像之间的帧曝光的同步,一个功能,最近才提供,而无需创建定制的解决方案。在这项工作中,我们考虑在成像容积描记中的用途多,市售的,同步成像器。于采用多成像器同步的市售溶液分析21静止的,就座参与者而地面实况生理信号同时进行测量。总共三个成像器被使用,有利于从所有三个成像器对从所述阵列中的单个中心成像数据融合的数据之间的比较。所述受试者内设计包括脉搏率和脉冲信噪比的分析。利用从三重成像器阵列融合数据,相比于每分钟7.4次用单个成像器在脉冲率测量平均绝对误差降低到3.8。尽管这代表了在多成像器的情况下的整体改善,还注意的是,这些错误是比可比研究中获得的那些高得多。我们进一步讨论这些结果及其影响使用容易获得的商业成像解决方案用于成像体积描记的应用程序。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号