In the frame of the Sentinel-2 Mission Performance Centre (MPC) activities, in order to assess the S2A/MSI data quality and to monitor its evolution, DIMITRI is used to perform the vicarious validation of the Level-1C products. DIMITRI consists on several vicarious calibration methodologies for EO optical sensors: Rayleigh scattering, Sun-Glint, PICS and sensor-tosensor inter-calibration. The first results of S2A/MSI from both Rayleigh and PICS methodologies are consistent and show an excellent quality of the L1C products. The crossmission Intercomparison with LANDSAT-8/OLI over PICS shows good agreement within the ±5% mission requirements. The Intercomparison with concomitant ground-based TOA-reflectance over the Railroad Valley site shows a good agreement with a relative difference of 5%-10%. The uncertainties over the estimated calibration coefficients overall the results are found to be less than 5% for most of the S2A/MSI spectral bands.
机译:在Sentinel-2任务性能中心(MPC)活动的框架中,为了评估S2A / MSI数据质量并监控其演变,DIMITRI用于执行Level-1C产品的替代验证。 DIMITRI包括用于EO光学传感器的几种替代校准方法:瑞利散射,太阳闪光,图片和传感器 - 色谱传感器间校准。来自瑞利和PICS方法的S2A / MSI的第一个结果是一致的,并显示出L1C产品的优异质量。与Pics的Landsat-8 / Oli的跨辐射相互作用在±5%的任务要求中显示出良好的一致性。在铁路谷地站点上的伴随地面TOA反射率的相互熟练术语表现出良好的一致性,相对差异为5%-10%。对于大多数S2A / MSI光谱带,发现估计校准系数上的不确定性总体上总体结果为小于5%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号