Experimental laboratory tests including density, water absorption, soluble salts, compressive strength and freeze-thaw (FT) resistance have been done on clay, concrete and silicate bricks from 6 masonry buildings in Latvia following CEN standards with adjustments for historic bricks. In addition, in-situ measurements of moisture content in brick masonry walls were done over a 5 month period using Trotec micro-wave apparatus. Laboratory findings include similarities to results of previous research, a surprising lack of quality in newer bricks, a low content of soluble salts and low FT resistance for Soviet-period silicate bricks. Wall measurements reveal the predicted drying in spring, less moisture in greater height and multiple spatial moisture tendencies that require further research.
机译:在拉脱维亚6架砖石建筑物之后,在历史型砖的调整后,在拉脱维亚的6种砌筑建筑物的粘土,混凝土和硅酸盐砖上进行了实验实验室试验,包括密度,吸水,可溶性盐,抗压强度和冷冻 - 解冻(FT)电阻。此外,使用Trotec Micro-Wave装置在5个月内完成砖砌体壁的水分含量的原位测量。实验室调查结果包括以前研究的结果的相似之处,较新砖的令人惊讶的缺乏质量,苏联硅酸盐砖的低含量含量和低的FT电阻。墙体测量揭示了春天的预测干燥,更低的高度和需要进一步研究的多种空间湿度倾向的水分。