Electrical Tests of Superconducting Busbar Insulation of ITER FEEDER PF4 CFT

机译:磨损器PF4 CFT超导母线绝缘的电气试验

获取原文

摘要

The busbar of PF4 CFT (Cryostat Feedthrough of No. 4 Poloidal Field Coil) have insulation which consists of several half-overlapped pre-preg and glass kapton. In this paper, three kinds of electrical tests for PF4 CFT busbar insulation acceptance were introduced, include Direct Current (DC) High Voltage (HV) test, Alternating Current (AC) Partial Discharge (PD) high voltage test, and Paschen test. The site environment control, electrodes connection configuration, and test processes of busbar insulation electrical tests are introduced. All the test electrical results can meet the production requirements greatly and gave a strong quality guarantee for insulation of PF4 CFT superconducting busbar.
机译:PF4 CFT的母线(4号球形磁线圈的Cryostat馈电)具有绝缘材料,其包括几个半重叠的预先预先预先Preg和玻璃Kapton。本文介绍了三种用于PF4 CFT母线绝缘接受的电气测试,包括直流(DC)高压(HV)测试,交流(AC)局部放电(PD)高压测试,以及Paschen测试。介绍了站点环境控制,电极连接配置和母线绝缘电气测试的测试过程。所有测试电气结果都可以大大满足生产要求,并为PF4 CFT超导母线绝缘提供了强大的质量保证。