首页> 外文会议>International Conference on Applied Superconductivity and Electromagnetic Devices >Electrical Tests of Superconducting Busbar Insulation of ITER FEEDER PF4 CFT
【24h】

Electrical Tests of Superconducting Busbar Insulation of ITER FEEDER PF4 CFT

机译:ITER FEEDER PF4 CFT超导母线绝缘的电气测试

获取原文

摘要

The busbar of PF4 CFT (Cryostat Feedthrough of No. 4 Poloidal Field Coil) have insulation which consists of several half-overlapped pre-preg and glass kapton. In this paper, three kinds of electrical tests for PF4 CFT busbar insulation acceptance were introduced, include Direct Current (DC) High Voltage (HV) test, Alternating Current (AC) Partial Discharge (PD) high voltage test, and Paschen test. The site environment control, electrodes connection configuration, and test processes of busbar insulation electrical tests are introduced. All the test electrical results can meet the production requirements greatly and gave a strong quality guarantee for insulation of PF4 CFT superconducting busbar.
机译:PF4 CFT(第4极场线圈的恒冷器馈通)的母线具有绝缘,该绝缘由几个半重叠的预浸料和玻璃棉组成。本文介绍了PF4 CFT母线绝缘验收的三种电气测试,包括直流(DC)高压(HV)测试,交流(AC)局部放电(PD)高压测试和Paschen测试。介绍了现场环境控制,电极连接配置以及母线绝缘电气测试的测试过程。所有的测试电气结果都可以很好地满足生产要求,并为PF4 CFT超导母线的绝缘提供了有力的质量保证。