首页> 外文会议>International Conference on Electrical Information and Mechatronics >Impact of Rotor Inter-turn Short-circuit on Generator Rotor Force
【24h】

Impact of Rotor Inter-turn Short-circuit on Generator Rotor Force

机译:转子匝间短路对发电机转子力的影响

获取原文

摘要

This paper analyzes the calculation method of unbalanced electromagnetic force by rotor winding inter-turn short-circuit fault, analytical calculating method neglects saturation, cogging and other factors, so the calculation accuracy is not high, in order to accurately calculate the magnetic field and the unbalanced electromagnetic force, this paper propose to analyze generator magnetic field by a finite element software Ansys, the obtained magnetic field data are further used to analyze the distributed electromagnetic force and the total force that generator rotor suffered, electromagnetic force distribution law of different slots, different levels of inter-turn short-circuit are got, which provide a basis for further studying the full force on generator rotor.
机译:本文分析了转子绕组匝间短路故障计算方法的计算方法,分析计算方法忽略了饱和,齿槽等因素,因此计算精度不高,以便准确计算磁场和不平衡电磁力,本文提出通过有限元软件ANSYS分析发电机磁场,所获得的磁场数据进一步用于分析分布式电磁力和发电机转子所遭受,电磁力分布规律的不同槽的总力, GOT的不同级别的匝间短路提供了进一步研究发电机转子的全部力的基础。