This paper mainly introduces that the overall simulation and numerical calculation model which includes the system of pumping station and groundwork is built to study the concrete structure of pumping station with 3-D finite element software Marc. By undertaking a study on stress and deformation of pumping station structure and combining the living example, the root cause of cracks is raised. By calculating and studying, the overall strength and displacement of structure can be reflected more intuitively and accurately with the method of 3-D finite element.
机译:本文主要介绍了包括泵站和地面系统的整体仿真和数值计算模型,以研究用三维有限元软件MARC研究泵站混凝土结构。通过对泵站结构的压力和变形进行研究并结合生活实例,提高了裂缝的根本原因。通过计算和研究,通过三维有限元的方法更直观,结构的整体强度和位移可以更直观,准确地反映。