Previous research has shown that the water-soluble carbohydrates (WSC) of Plantain {Plantago lanceolata L.) leaves differ from that of many other common forages. Analytical methods used to quantify WSC may underestimate the concentration of WSC in plantain herbage. To ascertain the suitability of current method, the conventional anthrone reaction method (AR) was compared against the phenol-sulphuric acid method (PSA). The WSC of eight plantain samples and one ryegrass sample were compared using AR and PSA against high-performance liquid chromatography (HPLC). The results showed that AR greatly underestimated the WSC content of plantain compared with PSA, which was similar to HPLC (7.18%, 13.5%, 14.7% DM, respectively, PO.001). The discrepancy between the results from AR and PSA was due to sorbitol, which was not detected using AR.
机译:以前的研究表明,Plantain {Plantago Lanceolata L.)叶子的水溶性碳水化合物(WSC)与许多其他常见饲料的水溶性碳水化合物(WSC)不同。用于量化WSC的分析方法可能低估了植物牧草中WSC的浓度。为了确定目前方法的适用性,将常规的蒽酮反应方法(Ar)与酚硫酸法(PSA)进行比较。使用AR和PSA对高性能液相色谱(HPLC)进行比较8种植物样品和一个Ryegrass样品的WSC。结果表明,与PSA相比,AR极大地低估了植物的WSC含量,其与HPLC类似(分别为7.18%,13.5%,14.7%DM,PO.001)。来自Ar和PSA的结果之间的差异是由于山梨糖醇,其未使用AR检测到。