Wastewater in cities and industry sectors is always characterized with high-salinity.In this paper,a novel mechanical vapor recompression evaporative crystallization system was proposed to treat high-salinity wastewater and realize zero-emission.A mathematical model was developed using the software Engineering Equation Solver(EES).The effects of the flashing pressure(Pflash),the feeding wastewater salinity(co),the first-effect evaporation concentration(c_(evap))and the water injection ratio(βv)on the coefficient of performance(COP),compression work(W_(comp))and circulation ratio(CR)were studied in detail.The results show that the c_(evap)has significant influence on the CR,especially when the c_(evap)is close to co;;the water injected MVR system obtains higher COP,and specifically,with the increase of the βv the COP improved nearly 5.0% for various operation conditions.
机译:城市和工业部门的废水始终具有高血管。本文提出了一种新型机械气相再压缩蒸发结晶系统,以处理高盐度废水,实现零排放。使用软件工程方程式开发了数学模型求解器(EES)。闪蒸(PFLASH)的效果(pflash),饲料废水盐度(CO),第一效应蒸发浓度(C_(evap))和水注射比(βv)对性能系数(COP ),详细研究了压缩工作(W_(COMP))和循环比(CR)。结果表明C_(evap)对CR有重大影响,特别是当C_(evap)接近CO ;;水注入的MVR系统获得更高的COP,具体地,随着βV的增加,COP的βV改善了各种操作条件的近5.0%。