首页> 外文会议>Applied Energy Symposium and Forum >Experimental study of an Adsorption Refrigeration Test Unit Lingbao Wanga'b>c'd,Xianbiao Buabc>*,WeibinMaabc”Guangzhou Institute of Energy Conversion,Chinese Academy of Sciences,Guangzhou 510640,China bCAS Key Laboratory of Renewable Energy,Guangzhou 510640,China’Guangdong Provincial Key Laboratory of New and Renewable Energy Research and Development,Guangzhou 510640,China’'University of Chinese Academy of Sciences,Beijing 100049,China
【24h】

Experimental study of an Adsorption Refrigeration Test Unit Lingbao Wanga'b>c'd,Xianbiao Buabc>*,WeibinMaabc”Guangzhou Institute of Energy Conversion,Chinese Academy of Sciences,Guangzhou 510640,China bCAS Key Laboratory of Renewable Energy,Guangzhou 510640,China’Guangdong Provincial Key Laboratory of New and Renewable Energy Research and Development,Guangzhou 510640,China’'University of Chinese Academy of Sciences,Beijing 100049,China

机译:吸附制冷试验单位凌宝王川> C'd,Xianbiao Buabc> *,Weibinmaabc“广州能源转换学院,中国科学院广州510640,中国广州市再生能源重点实验室,广州510640 “广东省新和可再生能源研发重点实验室,广州510640,中国科学院中国大学,北京100049

获取原文

摘要

Adsorption refrigeration has been considered as an important way to utilize low-grade thermal energy efficiently.To overcome the drawbacks of low coefficient of performance(COP)and specific cooling power(SCP),a novel adsorption refrigeration test unit is proposed.The experimental research has been carried out from the view of heat and mass performance enhancement of adsorber and modification of the system structure.The AQSOA coated heat exchanger supplied by Mitsubishi Plastics Inc.is employed as adsorber and the test unit is designed without vacuum valve and with a double-layers evaporator.It is indicated that the COP,SCP and volume cooling power density(SCPv)can reach 0.37,410.625 W/kg and 43 kW/kg,respectively,under the conditions of 90°C hot water temperature,35°C cooling water temperature,11°C chilled water temperature and 480 s optimal half cycle time.What is more,the effects of operating parameters,such as hot water temperature,cooling water temperature,chilled water temperature and structural form of the evaporator,on the adsorption performance are investigated in detail.It is demonstrated that it is feasible to utilize various low grade heat thermal energy.
机译:吸附制冷被认为是利用低级热能的重要方法。克服了低性能系数(COP)和特定冷却功率(SCP)的缺点,提出了一种新的吸附制冷试验单元。实验研究从热量和质量性能提高吸附剂的看法和系统结构的修改。Mitsubishi Plastics Inc.is提供的AQSOA涂层热交换器,用于吸附器和试验装置,无真空阀门设计,双重 - 形式蒸发器。表明COP,SCP和音量冷却功率密度(SCPV)可分别达到0.37,410.625W / kg和43 kW / kg,在90°C热水温度的条件下,35°C冷却水温,11℃冷水温度和480秒的最佳半周期时间。操作参数的影响是多项,效果,如热水温度,冷却水温,冷却水温蒸发器的结构形式,详细研究了吸附性能。说明利用各种低级热热能是可行的。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号