Ultra-short, high-dose rate digital x-ray tube based on carbon nanotube emitters for advanced cone-beam breast computed tomography

机译:基于碳纳米管发射器的超短,高剂量速率数字X射线管,用于高级锥形梁乳房计算断层扫描

获取原文

摘要

Cone-beam breast computed tomography (CBCT) would be a promising modality in screening and diagnosis of breast, providing complete 3-dimensional images with little painful compression of breast during the imaging compared to conventional mammography and tomosynthesis. To date, all CBCT systems including a commercial one by Koning have been utilizing a typical filament-based x-ray tube. However, the filament-based x-ray tube even in a grid type has strict limitation in time resolution, of longer than few milliseconds, with a limited dose rate to cause a large motion blur in CBCT projection images. Micro-calcifications of less than 1 mm in early breast cancer could be hardly distinguished by using conventional CBCT systems. We tried to solve this problem by adopting a fast digital x-ray tube based on carbon nanotube (CNT) field emitters. We, for the first time, developed a rotational anode x-ray tube with CNT emitters for advanced CBCTs. The x-ray tube consisted of CNT paste-emitters and a rotating anode made of W/Re target, and was fully vacuum-sealed with a glass envelope. Ultra-short x-ray pulses of less than sub-ms with a moderate high current of more than 200 mA and a focal spot of ~0.3 in nominal value was successfully obtained. We performed preliminary studies on CBCT imaging using the digital x-ray tube and achieved 300 projection images for 10 s, great reducing motion blurs in the images. It is expected that the CNT digital x-ray tube developed improves CBCT imaging greatly and then promotes CBCT modality in breast screening and diagnosis.
机译:锥梁乳房计算机断层扫描(CBCT)是筛选和诊断乳房的有希望的方式,提供完整的三维图像,其在成像期间与常规乳房X线照相术和Tomos合成相比,在成像期间具有很少的痛苦压缩。迄今为止,所有CBCT系统包括由koning的商业人员一直利用典型的丝基X射线管。然而,即使在网格型中,基于丝的X射线管也具有严格的时间分辨率,超过少于几毫秒,剂量率有限,以引起CBCT投影图像中的大运动模糊。通过使用常规CBCT系统,可能几乎不能区分早期乳腺癌在早期乳腺癌中小于1mm的微钙化。我们试图通过采用基于碳纳米管(CNT)场发射器的快速数字X射线管来解决这个问题。我们首次开发出具有用于高级CBCT的CNT发射器的旋转阳极X射线管。 X射线管由CNT浆料发射器和由W / RE靶制成的旋转阳极组成,并且用玻璃包络完全真空密封。成功地获得超短X射线脉冲,较小的高电流超过200mA的中等高电流和标称值以〜0.3的焦点。我们使用数字X射线管对CBCT成像进行了初步研究,并在图像中实现了300个投影图像,在图像中大的减少运动模糊。预计CNT数字X射线管开发的CNT数字X射线管大大改善了CBCT成像,然后促进了乳腺筛选和诊断中的CBCT模态。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号