Steel has been used for many decades in structural applications because of its good combination of mechanical properties. In recent years in Bangladesh the demand for TMT 500W steel bars has increased profoundly, for its higher strength and good ductility. But fire remains one of the serious potential risks to most buildings and structures. To understand the effect of fire on mechanical properties of steel bars at elevated temperature a locally produced 500W TMT bar of 8 mm diameter has been investigated. Both macroscopy and microscopy were carried out to reveal different zones such as hardened case, soft core and transition zone in the cross-section and microstructure respectively of the steel bars in the as received condition. Finally, high temperature tensile tests were conducted at 500°C, 600°C, 650°C in steady state method at a strain rate of 0.5mm/min and the results at these 3 temperatures were noted. Data generated from the room temperature and high temperature tensile tests were compared. The test results demonstrated that the high temperature severely degrades the tensile strength of the 500W TMT steel bars and they can hardly bear any load at temperature above 600°C.
机译:由于其良好的机械性能组合,钢已在结构应用中使用了数十年。近年来,孟加拉国对TMT 500W钢筋的需求越来越大,因为其更高的强度和良好的延展性。但是,火灾仍然是大多数建筑物和结构的严重潜在风险之一。要了解火灾对钢筋机械性能的升高温度,已经研究了8毫米直径的局部产生的500W TMT棒。进行宏观和显微镜检查,以在作为所接收的条件下分别在横截面和微观结构中的横截面和微观结构中的不同区域露出不同的区域。最后,在500℃,600℃,650℃下以0.5mm / min的应变速率在稳态方法中进行高温拉伸试验,并注意到这些3温度的结果。比较了从室温和高温拉伸试验产生的数据。测试结果表明,高温严重降低了500W TMT钢筋的拉伸强度,并且它们在600℃的温度下几乎不能承受任何负载。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号