首页> 外文会议>International Symposium on Advanced Materials and Application >Failure on Bearing Cooler Coils Connector of Hydroelectric Power Plant
【24h】

Failure on Bearing Cooler Coils Connector of Hydroelectric Power Plant

机译:水电站轴承冷却器连接器的失效

获取原文

摘要

Bearing cooler coils connector of 175 MW hydropower plant experienced premature leaks after one year operation and caused an unscheduled shutdown. To avoid the same failure in the future, the leaking bearing cooler coils connector was investigated. Nondestructive tests, such as chemical composition analysis, hardness test, metallographic test, characterization of the filler brazing by scanning electron microscopy - energy dispersive X-ray spectroscopy were conducted. The results confirmed that the bearing cooler coils connector consisted of two types of material namely the flange material which was made of stainless steel 304 and the pipe material which was a Cu/Ni 90/10 and were joined together using brazing process. It was a clearly evidence that leaks occurred in the brazing area and the leakage was due to improper brazing process. It was shown by the excessive gap and a lot of porosity.
机译:轴承冷却器线圈连接器175 MW水电站经过一年的运行后经历过早泄漏,造成了未划伤的关机。为了避免对未来相同的故障,研究了泄漏的轴承冷却器线圈连接器。无损检测,如化学成分分析,硬度试验,金相试验,通过扫描电子显微镜 - 能量分散X射线光谱进行填料钎焊的表征。结果证实,轴承冷却器线圈连接器由两种类型的材料组成,即由不锈钢304和作为Cu / Ni 90/10的管材制成的凸缘材料,并且使用钎焊工艺连接在一起。这是一个明确的证据表明钎焊区域发生泄漏,泄漏是由于钎焊过程不当。它被过度的间隙和大量孔隙率所示。

著录项