首页> 外文会议>International Conference on Acoustics and Vibration of Mechanical Structures >Dynamic Analysis of the Reaction Chamber for the ELIADE Array
【24h】

Dynamic Analysis of the Reaction Chamber for the ELIADE Array

机译:ELIADE阵列反应室的动态分析

获取原文

摘要

The ELI-NP Array of DEtectors (ELIADE) is one of the experimental setups being built at ELI-NP. The reaction chamber for the ELIADE array is, together with the CCD camera the goal of research team. The precision of the experiment make important the small deformation and the vibration of the equipment. To study this, a model using Finite Element Method is used. The device consists of elastic elements to a smaller or greater extent. Usually, if the velocities and the occurring loads are low then the rigid elements hypothesis can lead to an excellent model. But in the experiment that will be conduct in the laboratory with ELIADE, precision is so important that it require extremely small deformation of the device. For this a model that takes into account the elasticity of the body must be used in order to study the movement of the part of the device during the experiment.
机译:ELI-NP探测器阵列(ELIADE)是ELI-NP建造的实验设置之一。 ELIADE阵列的反应室与CCD相机一起进行了研究团队的目标。实验的精度具有重要的变形和设备的振动。为此,使用使用有限元方法的模型。该装置由弹性元件组成,以更小或更大程度。通常,如果速度和发生的载荷低,则刚性元件假设可以导致优异的模型。但在实验中,将在实验室进行ELIADE,精确度非常重要,这需要极小的装置变形。对于该模型,考虑到身体的弹性,以便在实验期间研究装置的一部分的运动。