摘要

Laboratory studies were undertaken to understand the low frequency response of thermally degraded stator winding insulation. The dielectric diagnostic methods namely capacitance and tan δ measurements at different frequencies (Dielectric spectroscopy a frequency domain method) and Recovery voltage measurement (time domain method) has been used to study the dielectric response of epoxy mica insulation. Two different types of insulation systems namely Epoxy-Mica resin poor and epoxy-Mica resin rich system are evaluated. Low voltage measurements at 140 volts peak were made in the frequency range of 1 mHz to 1 kHz using Dielectric spectroscopy. The Recovery voltage measurement technique was adopted to investigate the slow polarization process in the dielectric and to assess the insulation ageing based on the analysis of polarization spectrum. This paper presents the dielectric response of epoxy mica insulation system subjected to thermal ageing.
机译:进行了实验室研究以了解热降解定子绕组绝缘的低频响应。介电诊断方法包括不同频率的电容和TANδ测量(介电光谱A频域方法)和恢复电压测量(时域方法)已经用于研究环氧云母绝缘的介电响应。评估两种不同类型的绝缘系统即环氧树脂树脂差和环氧云母树脂富含系统。使用介电光谱法在1MHz至1kHz的频率范围内为140伏峰处的低电压测量。采用恢复电压测量技术来研究电介质中的慢偏振过程,并根据偏振谱分析评估绝缘老化。本文介绍了对热老化的环氧云母绝缘系统的介电响应。