Laboratory studies were undertaken to understand the low frequency response of thermally degraded stator winding insulation. The dielectric diagnostic methods namely capacitance and tan δ measurements at different frequencies (Dielectric spectroscopy a frequency domain method) and Recovery voltage measurement (time domain method) has been used to study the dielectric response of epoxy mica insulation. Two different types of insulation systems namely Epoxy-Mica resin poor and epoxy-Mica resin rich system are evaluated. Low voltage measurements at 140 volts peak were made in the frequency range of 1 mHz to 1 kHz using Dielectric spectroscopy. The Recovery voltage measurement technique was adopted to investigate the slow polarization process in the dielectric and to assess the insulation ageing based on the analysis of polarization spectrum. This paper presents the dielectric response of epoxy mica insulation system subjected to thermal ageing.
机译:进行了实验室研究,以了解热降解定子绕组绝缘的低频响应。介电诊断方法,即在不同频率下的电容和tanδ测量(介电谱,频域方法)和恢复电压测量(时域法)已用于研究环氧云母绝缘的介电响应。对两种不同类型的绝缘系统进行了评估,分别是贫环氧云母树脂体系和富环氧云母树脂体系。使用介电光谱法在1 mHz至1 kHz的频率范围内进行140伏峰值的低压测量。采用恢复电压测量技术研究电介质中的慢极化过程,并根据极化光谱分析评估绝缘老化。本文介绍了热老化的环氧云母绝缘系统的介电响应。